{"product_id":"tomzn-10in1-multi-function-time-relay-delay-interval-repeat-cycle-single-shot-latching-relay-pulse-generator-ac230v-16a-18mm","title":"TOMZN 10IN1 Multi-function Time Relay Delay Interval Repeat Cycle Single Shot Latching Relay Pulse Generator AC230V 16A 18mm","description":"\u003ch1\u003eSPECIFICATIONS\u003c\/h1\u003e\u003cp\u003e\u003cspan\u003eBrand Name\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eTOMZN\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eCertification\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eCE\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eContact Arrange\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eSPDT\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eContact Load\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eLow Power\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eEU LVD Voltage\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eHigh voltage: Above 50Vac or 75Vdc\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eHigh-concerned chemical\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eNone\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eModel Number\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eTORT7-M1\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eOrigin\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eMainland China\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003ePower Source\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eAc,Ac\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eTIME\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003e0.1s-10days\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eTheory\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eTime Relay\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eUse\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eGeneral Purpose\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eVOLT\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eAC230V 50\/60Hz\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eVoltage\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003e220V\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eis_customized\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eYes\u003c\/span\u003e\u003c\/p\u003e\u003cdiv class=\"detailmodule_html\"\u003e\u003cdiv class=\"detail-desc-decorate-richtext\"\u003e\n\u003cdiv class=\"detailmodule_dynamic\"\u003e\u003ckse:widget data-widget-type=\"customText\" id=\"32676104\" type=\"custom\"\u003e\u003c\/kse:widget\u003e\u003c\/div\u003e\n\u003cp style=\"margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:border-box\"\u003e\u003cspan style=\"font-size:24px;font-family:Arial\"\u003e\u003cstrong\u003eTORT7-M1 10 in 1 Multi-function time relay\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:border-box\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp style=\"margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:border-box\"\u003e\u003cspan style=\"font-size:24px;font-family:Arial\"\u003e\u003cstrong\u003e1.General\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom:16px;margin-top:16px\" class=\"ds-markdown-paragraph\"\u003e\u003cspan style=\"font-size:18px;font-family:Arial\"\u003e  TORT7-M1 is a versatile solution for controlling electrical appliances, lighting, heating, motors, pumps, and fans. It offers 10 timing functions and 10 adjustable time ranges, from 0.1 seconds to 10 days, all easily set via user-friendly rotary switches. Supporting multi-voltage applications, this compact DIN rail module provides reliable automation with a clear LED status indicator for seamless integration into various control systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"letter-spacing:normal;white-space:normal;border-bottom:0px;border-left:0px;border-right:0px;border-top:0px;margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:content-box\"\u003e\u003cspan style=\"font-size:24px;font-family:Arial\"\u003e\u003cstrong\u003e2.Technical Data\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:Arial\"\u003eModel: TORT7-M1\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom:16px;margin-top:16px\" class=\"ds-markdown-paragraph\"\u003e\u003cspan style=\"font-family:Arial\"\u003e\u003cspan style=\"font-size:18px\"\u003eFunctions:\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cp\u003e\u003cspan style=\"font-family:Arial\"\u003e\u003cspan style=\"font-size:18px\"\u003e5 time functions controlled by supply voltage\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cspan style=\"font-family:Arial\"\u003e\u003cspan style=\"font-size:18px\"\u003e4 time functions controlled by control input\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cspan style=\"font-family:Arial\"\u003e\u003cspan style=\"font-size:18px\"\u003e1 function of latching relay\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:Arial\"\u003eVoltage range: AC230V (50\/60Hz)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:Arial\"\u003ePower input: AC max.6VA\/1.3W\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:Arial\"\u003eSupply voltage tolerance: -15%;+10%\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:Arial\"\u003eTime ranges: 0.1s-10days,ON,OFF\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:Arial\"\u003eTime setting: Potentionmeter\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:Arial\"\u003eTime deviation: 10%-mechanical setting\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:Arial\"\u003eRepeat accuracy: 0.2%-set value stability\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:Arial\"\u003eTemperature coecient: 0.05%\/C,at=20°C(0.05%，at=68℉)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:Arial\"\u003eOutput: 1xSPDT\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:Arial\"\u003eCurrent rating: 16A\/AC1\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:Arial\"\u003eSwitching voltage: 250VAC\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:Arial\"\u003eMin.breaking capacity DC: 500mW\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:Arial\"\u003eSupply indication: green LED\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:Arial\"\u003eOutput indication: red LED\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:Arial\"\u003eMechanical life: 1x107\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:Arial\"\u003eElectrical life: 1x105\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:Arial\"\u003eReset time: max.200ms\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:Arial\"\u003eOperating temperature: -20℃ to +55℃\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:Arial\"\u003eStorage temperature: -35°C to +75°C\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:Arial\"\u003eMounting\/DIN rail: Din rail EN\/IEC 60715\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:Arial\"\u003eProtection degree: IP40 for front panel\/IP20 terminals\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:Arial\"\u003eOperating position: any\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:Arial\"\u003eOvervoltage cathegory: III.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:Arial\"\u003ePollution degree: 2\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:Arial\"\u003eMax.cable size(mm2): solid wire max.1x2.5 or 2x1.5\/with sleeve max.1x2.5(AWG 12)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:Arial\"\u003eTightening torque: 0.4Nm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:Arial\"\u003eDimensions: 90x18x64mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:Arial\"\u003eStandards: EN 61812-1,EC60947-5-1\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:24px;font-family:Arial\"\u003e\u003cstrong\u003e3.\u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"font-family:Arial\"\u003e\u003cspan style=\"font-size:24px\"\u003e\u003cstrong\u003eFunction Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:20px;font-family:Arial\"\u003eA:On Delay (Power On)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-family:Arial\"\u003e\u003cspan style=\"font-size:20px\"\u003eWhen the input voltage U is applied, timing delay t begins. Relay contacts R change state after time delay is complete. Contacts R return to their shelf state when input voltage U is removed. Trigger switch is not used in this function.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-family:Arial\"\u003e\u003cspan style=\"font-size:20px\"\u003eB:Interval(Power On)\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-family:Arial\"\u003e\u003cspan style=\"font-size:20px\"\u003eWhen input voltage U is applied, relay contacts R change state immediately and timing cycle begins. When time delay is complete, contacts return to shelf state, When input voltage U is removed contacts will also return to their shelf state.Trigger switch is not used in this function.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-family:Arial\"\u003e\u003cspan style=\"font-size:20px\"\u003eC:Repeat Cycle (Starting Off)\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-family:Arial\"\u003e\u003cspan style=\"font-size:20px\"\u003eWhen input voltage U is applied, lime delay t begins. When time delay t is complete, relay contacts R change state for time delay t. This cycle will repeat until input voltage U is removed. Trigger switch is not used in this function.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-family:Arial\"\u003e\u003cspan style=\"font-size:20px\"\u003eD:Repeat Cycle (Starting On)\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-family:Arial\"\u003e\u003cspan style=\"font-size:20px\"\u003eWhen input voltage U is applied, relay contacts R change state immediately and time delay t begins.When time delay t is complete, contacts return to their shelf state for time delay t, This cycle will repeat until input voltage U is removed, Trigger switch is not used in this function.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-family:Arial\"\u003e\u003cspan style=\"font-size:20px\"\u003eE:Off Delay (S Break)\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-family:Arial\"\u003e\u003cspan style=\"font-size:20px\"\u003eInput voltage U must be applied continuously, When trigger switch S is closed, relay contacts R change state, When trigger switch S is opened, delay t begins, when delay t is complete, contacts R return to their shelf state.If trigger switch S is closed before time delay t is complete, then time is reset, When trigger switch S is opened, the delay begins again, and relay contacts R remain in their energized state, lf input voltage U is removed.relay contacts R return to their shelf state.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-family:Arial\"\u003e\u003cspan style=\"font-size:20px\"\u003eF:Single Shot\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-family:Arial\"\u003e\u003cspan style=\"font-size:20px\"\u003eUpon application of input voltage U, the relay is ready to accept trigger signal S. Upon application of the trigger signal S, the relay contacts R transfer and the preset time t begins. During time-out, the trigger signal S is ignored, The relay resets by applying the trigger switch S when the relay is not energized.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-family:Arial\"\u003e\u003cspan style=\"font-size:20px\"\u003eG:Single Shot Trailing Edge (Non-Retriggerable）\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-family:Arial\"\u003e\u003cspan style=\"font-size:20px\"\u003eUpon application of input voltage U, the relay is ready to accept trigger signal S. Upon application of the trigger signal S, the relay contacts R transfer and the preset time t begins. At the end of the preset time t, the relay contacts R return to their normal condition unless the trigger switch S is opened and closed prior to time out t (before preset time elapses). Continuous cycling of the trigger switch S at a rate faster than the preset time will cause the relay contacts R to remain closed. lf input voltage U is removed, relay contacts R return to their shelf state.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-family:Arial\"\u003e\u003cspan style=\"font-size:20px\"\u003eH:On\/Off Delay\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-family:Arial\"\u003e\u003cspan style=\"font-size:20px\"\u003eInput voltage U must be applied continuously. When trigger switch S is closed, time delay t begins. When time delay t is complete, relay contacts R change state and remain transferred until trigger switch S is opened.If input voltage U is removed, relay contacts R return to their shelf state\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:20px;font-family:Arial\"\u003eNote:To ensure reliable operation, install this electrical device in a standard cabinet away from interference sources, using protective measures and verifying system compatibility.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-family:Arial\"\u003e\u003cspan style=\"font-size:20px\"\u003eI:Latching relay\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-family:Arial\"\u003e\u003cspan style=\"font-size:20px\"\u003eInput voltage U must be applied continuously. Output changes state with every trigger switch S closure. lf input voltage U is removed,relay contacts R return to their shelf state.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-family:Arial\"\u003e\u003cspan style=\"font-size:20px\"\u003eJ:Pulse generator\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-family:Arial\"\u003e\u003cspan style=\"font-size:20px\"\u003eUpon application of input voltage U, a single output pulse of 0.5 seconds is delivered to relay after time delay t. Power must be removed and re-applied to repeat pulse. Trigger switch is not used in this function.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cimg style=\"width:1000px\" width=\"1000px\" src=\"https:\/\/ae01.alicdn.com\/kf\/S969fa7580d3d4e56a767e471eae208acq.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg style=\"width:1000px\" width=\"1000px\" src=\"https:\/\/ae01.alicdn.com\/kf\/S25cf29ca8dca4f959c0f5d11517763877.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg style=\"width:1000px\" width=\"1000px\" src=\"https:\/\/ae01.alicdn.com\/kf\/S8c26da8383df402cbfbec7cc7ac9e8dbE.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg style=\"width:1000px\" width=\"1000px\" src=\"https:\/\/ae01.alicdn.com\/kf\/S15c78659525e4aff9124d8ced3ab218dA.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg style=\"width:1000px\" width=\"1000px\" src=\"https:\/\/ae01.alicdn.com\/kf\/Sd0920d726f984985a8f4728ae1d86271B.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg style=\"width:1000px\" width=\"1000px\" src=\"https:\/\/ae01.alicdn.com\/kf\/S502c9ccad44843e6bc330411d742db97v.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg style=\"width:1000px\" width=\"1000px\" src=\"https:\/\/ae01.alicdn.com\/kf\/S9b4454dd572242e3be99b80dc3f32f44V.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg style=\"width:1000px\" width=\"1000px\" src=\"https:\/\/ae01.alicdn.com\/kf\/S4382c92252c6496dab7390e095b0d37b5.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg style=\"width:1000px\" width=\"1000px\" src=\"https:\/\/ae01.alicdn.com\/kf\/Sf97d9b0c1389466b90cdd62700021d5eY.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cp\u003e\u003cimg style=\"width:1000px\" width=\"1000px\" src=\"https:\/\/ae01.alicdn.com\/kf\/Sa462f13ffa4746ac831fbe66a1e910bdM.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"54 Energy - Renewable Energy Store","offers":[{"title":"TORT7-M1 \/ AC230V 16A 50-60Hz","offer_id":68139333189949,"sku":"1005010354520240-TORT7-M1-AC230V 16A 50-60Hz","price":18.34,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0853\/3924\/2813\/files\/Sf013ca7525c2416080488cb346c95d81h.webp?v=1795191297","url":"https:\/\/54energy.net\/es\/products\/tomzn-10in1-multi-function-time-relay-delay-interval-repeat-cycle-single-shot-latching-relay-pulse-generator-ac230v-16a-18mm","provider":"54 Energy - Renewable Energy Store","version":"1.0","type":"link"}