{"product_id":"tomzn-din-rail-230vac-40a-3led-separate-indicator-auto-reconnect-over-under-voltage-protective-device-protector-protection-relay","title":"TOMZN DIN Rail 230VAC 40A 3LED Separate Indicator Auto Reconnect Over\/Under Voltage Protective Device Protector Protection Relay","description":"\u003ch1\u003eSPECIFICATIONS\u003c\/h1\u003e\u003cp\u003e\u003cspan\u003eBrand Name\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eTOMZN\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eCertification\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eCE\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eChoice\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eyes\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eDoes it include a Battery?\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eNo\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eDoes it include wireless functionality?\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eNo\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eEU LVD Voltage\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eHigh voltage: Above 50Vac or 75Vdc\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eHigh-concerned chemical\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eNone\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eIs Smart Device\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eno\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eModel Number\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eTOVPD1-60 3LED\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eOrigin\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eMainland China\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eRated Voltage\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003e220V\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eType\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eOther,Voltage relay\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eis_customized\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eYes\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003esemi_Choice\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eyes\u003c\/span\u003e\u003c\/p\u003e\u003cdiv class=\"detailmodule_html\"\u003e\u003cdiv class=\"detail-desc-decorate-richtext\"\u003e\n\u003cdiv class=\"detailmodule_dynamic\"\u003e\u003ckse:widget data-widget-type=\"customText\" id=\"32676104\" type=\"custom\"\u003e\u003c\/kse:widget\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan style=\"color:rgb(224, 62, 45)\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:24px;font-family:arial, helvetica, sans-serif\"\u003eUnder and over voltage protector\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color:rgb(224, 62, 45)\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:24px;font-family:arial, helvetica, sans-serif\"\u003eNoted: When you first connect the product, you have to wait about 1 minute, after the red light turn off, then the product will work.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003cspan style=\"font-size:24px;font-family:arial, helvetica, sans-serif\"\u003e1.General\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003eThe automatic recovery over voltage and under voltage protective device complies with modular design standards. the circuit boards of products adopt good quality electronic components with reliable performance. when the power situation is unstable. It's protection function will be automatically activated. once the voltage exceeds the limited range of products, it will automatically cut off so as to protect the safely of electrical equipment and persons. The device will re-supply in 1 minute, when the power returns to normal.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003eThe green indicator display, when the power is normal supply.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003eThe red indicator display, when the power over voltage or under voltage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cspan style=\"font-size:24px\"\u003e\u003cstrong\u003e\u003cspan style=\"font-family:arial, helvetica, sans-serif\"\u003e2.Main Technical Speacification\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003e1. Rated AC voltage: 230V±10% 50\/60Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003e2. Passing Max Current: 40A\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003e3. Max. Loading power: 8.8kVA\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003e4. Over-voltage action cut-off value: \u0026gt;270VAC±5V\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003e5. Normal-voltage value: 175-270VAC\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003e6. Under-voltage action cut-off value: \u0026lt;170VAC±5V\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003e7. Over voltage and under voltage cut off:\u0026lt; 1s\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003e8. Electricity transmitting delay after cut off: \u0026lt;60s\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003e9. Self power consumption: \u0026lt;2W\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003e10. Electric machinery life: 100000 times\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003e11. Dimension: 67*36*82mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003e12. Installing: 35mm Din rail\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003e13.3 LED LAMP: Power、Under voltage indicator、Over voltage indicator\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003e14. Wiring: Top input, bottom output\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg style=\"margin-left:auto;margin-right:auto;display:block;width:903px\" width=\"903px\" src=\"https:\/\/ae01.alicdn.com\/kf\/Sf8a395f8cb6e4a7d9d0cd7eb4d954e094.jpg\" slate-data-type=\"image\"\u003e\u003cimg style=\"margin-left:auto;margin-right:auto;display:block;width:903px\" width=\"903px\" src=\"https:\/\/ae01.alicdn.com\/kf\/S7c0fd2bf2ef748e192a610d98ad2cca9W.jpg\" slate-data-type=\"image\"\u003e\u003cimg style=\"margin-left:auto;margin-right:auto;display:block;width:903px\" width=\"903px\" src=\"https:\/\/ae01.alicdn.com\/kf\/S47401d0ba313499d9b7f4a291c2eb272B.jpg\" slate-data-type=\"image\"\u003e\u003cimg style=\"margin-left:auto;margin-right:auto;display:block;width:903px\" width=\"903px\" src=\"https:\/\/ae01.alicdn.com\/kf\/Sc40d2a1c11904ec28431f82d708358ecr.jpg\" slate-data-type=\"image\"\u003e\u003cimg style=\"margin-left:auto;margin-right:auto;display:block;width:903px\" width=\"903px\" src=\"https:\/\/ae01.alicdn.com\/kf\/Sf5f83291b3e4479d8912049d6447f4e4C.jpg\" slate-data-type=\"image\"\u003e\u003cimg style=\"margin-left:auto;margin-right:auto;display:block;width:903px\" width=\"903px\" src=\"https:\/\/ae01.alicdn.com\/kf\/S6716ec6361024fdc93d17b51322e9be3L.jpg\" slate-data-type=\"image\"\u003e\u003cimg style=\"margin-left:auto;margin-right:auto;display:block;width:903px\" width=\"903px\" src=\"https:\/\/ae01.alicdn.com\/kf\/S45641494833c4f13894c08592c86ba84U.jpg\" slate-data-type=\"image\"\u003e\u003cimg style=\"margin-left:auto;margin-right:auto;display:block;width:903px\" width=\"903px\" src=\"https:\/\/ae01.alicdn.com\/kf\/S922c87ff5a464391b91b3c721598bd28I.jpg\" slate-data-type=\"image\"\u003e\u003cimg style=\"margin-left:auto;margin-right:auto;display:block;width:903px\" width=\"903px\" src=\"https:\/\/ae01.alicdn.com\/kf\/S7d3d73ed62a248ec9ffcddedffafe244T.jpg\" slate-data-type=\"image\"\u003e\u003cimg style=\"margin-left:auto;margin-right:auto;display:block;width:903px\" width=\"903px\" src=\"https:\/\/ae01.alicdn.com\/kf\/S1480069368fa4a1dbc087f0897429178W.jpg\" slate-data-type=\"image\"\u003e\u003cimg style=\"margin-left:auto;margin-right:auto;display:block;width:903px\" width=\"903px\" src=\"https:\/\/ae01.alicdn.com\/kf\/S77efccc8c5844a739d06bd9c6d0bf969d.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"54 Energy - Renewable Energy Store","offers":[{"title":"2P 230VAC 40A 3LED","offer_id":68110462419261,"sku":"1005010366242912-2P 230VAC 40A 3LED","price":11.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0853\/3924\/2813\/files\/S4cb2d3b6502c4157966f840483195a98B.webp?v=1795037354","url":"https:\/\/54energy.net\/products\/tomzn-din-rail-230vac-40a-3led-separate-indicator-auto-reconnect-over-under-voltage-protective-device-protector-protection-relay","provider":"54 Energy - Renewable Energy Store","version":"1.0","type":"link"}