{"product_id":"tomzn-split-core-current-transformer-current-sensor-ct-400a-600a-800a-1000a-ac-for-energy-meter-kwh-meter-power-monitoring-abs","title":"TOMZN Split Core Current Transformer Current Sensor CT 400A 600A 800A 1000A AC for Energy Meter kWh Meter Power Monitoring ABS","description":"\u003ch1\u003eSPECIFICATIONS\u003c\/h1\u003e\u003cp\u003e\u003cspan\u003eBrand Name\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eTOMZN\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eCertification\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eCE\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eCoil Number\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eAutotransformer\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eDoes it include a Battery?\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eNo\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eDoes it include wireless functionality?\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eNo\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eEU LVD Voltage\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eHigh voltage: Above 50Vac or 75Vdc\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eHigh-concerned chemical\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eNone\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eModel Number\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eKCT-50\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eOrigin\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eMainland China\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003ePhase\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eSINGLE\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eUse\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eCurrent\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eis_customized\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eYes\u003c\/span\u003e\u003c\/p\u003e\u003cdiv class=\"detailmodule_html\"\u003e\u003cdiv class=\"detail-desc-decorate-richtext\"\u003e\n \u003cp\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: 18px;\"\u003eKCT-50 Split type CT\u003c\/span\u003e\u003c\/p\u003e\n \u003cp\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: 18px;\"\u003e400A\/600A\/800A\/1000A to 5A\u003c\/span\u003e\u003c\/p\u003e\n \u003cp\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: 18px;\"\u003eBore diameter: 50mm\u003c\/span\u003e\u003c\/p\u003e\n \u003cp\u003e \u003c\/p\u003e\n \u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: 24px;\"\u003eGeneral\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n \u003cp\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: 18px;\"\u003e  The KCT-50 is a split-type (split-core) current transformer engineered for quick, tool-free installation: the core opens to clip directly around an existing cable or busbar, so heavy conductors never need to be disconnected. With a rated primary current of 400A \/ 600A \/ 800A \/ 1000A and a standard 5A secondary output, it accurately steps down high line currents for conventional meters, relays, and protection instruments.\u003c\/span\u003e\u003c\/p\u003e\n \u003cp\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: 18px;\"\u003e  Its 50mm bore diameter easily accommodates the large conductors and busbars found in distribution cabinets and substations, while the split-core construction makes it the ideal choice for retrofitting energy monitoring onto live or existing systems — installation takes seconds with no service interruption. Compliant with IEC 60044-1, the KCT-50 delivers dependable, repeatable measurement performance for monitoring, protection, and metering duties.\u003c\/span\u003e\u003c\/p\u003e\n \u003cp\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: 18px;\"\u003e  Built for industrial environments, this transformer suits distribution cabinets, substations, and industrial power systems where accurate current sensing, easy installation, and long-term reliability are essential.\u003c\/span\u003e\u003c\/p\u003e\n \u003cp\u003e \u003c\/p\u003e\n \u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: 24px;\"\u003eProduct parameters\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n \u003cp\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: 18px;\"\u003eProduct Name: KCT-50 Split-Core Current Transformer\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: 18px;\"\u003eModel: KCT-50\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: 18px;\"\u003eType: Split-Type (Split-Core) Current Transformer\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: 18px;\"\u003eRated Primary Current: 400A\/600A\/800A\/1000A\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: 18px;\"\u003eRated Secondary Current: 5A\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: 18px;\"\u003eTransformation Ratio: 400:5 \/ 600:5 \/ 800:5 \/ 1000:5\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: 18px;\"\u003eBore (Window) Diameter: 50mm\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: 18px;\"\u003eInstallation: Split-core — clips around the primary conductor without disconnection\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: 18px;\"\u003eFunction: Monitoring\/Protection\/Metering\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: 18px;\"\u003eCompliance Standard: IEC 60044-1\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: 18px;\"\u003eApplication: Distribution cabinets、Substations、Industrial power systems\u003c\/span\u003e\u003c\/p\u003e\n \u003cp\u003e \u003c\/p\u003e\n \u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: 24px;\"\u003eNoted\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: 18px;\"\u003e1. The CT primary should be connected in series with the test current loop, the secondary should be as work in the short-circuit state.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: 18px;\"\u003e2. The secondary circuit is not allowed open circuit, so please do not install fuse.\u003c\/span\u003e\u003c\/p\u003e\n \u003cp\u003e\u003cimg style=\"width: 900.6944580078125px;display: block; margin-left: auto; margin-right: auto;\" src=\"https:\/\/ae-pic-a1.aliexpress-media.com\/kf\/S648a233f126a4b91864596a6ea277cc0D.jpg\" width=\"900.6944580078125\"\u003e\u003cimg style=\"width: 900.6944580078125px;display: block; margin-left: auto; margin-right: auto;\" src=\"https:\/\/ae-pic-a1.aliexpress-media.com\/kf\/S05ed6dfa7b754803b4d473b5981970b2O.jpg\" width=\"900.6944580078125\"\u003e\u003cimg style=\"width: 900.6944580078125px;display: block; margin-left: auto; margin-right: auto;\" src=\"https:\/\/ae-pic-a1.aliexpress-media.com\/kf\/S4f6be9958395477ba7dd86703588c023L.jpg\" width=\"900.6944580078125\"\u003e\u003cimg style=\"width: 900.6944580078125px;display: block; margin-left: auto; margin-right: auto;\" src=\"https:\/\/ae-pic-a1.aliexpress-media.com\/kf\/S7f9d1ecc7da9416e977d00b0ff26fc54F.jpg\" width=\"900.6944580078125\"\u003e\u003cimg style=\"width: 900.6944580078125px;display: block; margin-left: auto; margin-right: auto;\" src=\"https:\/\/ae-pic-a1.aliexpress-media.com\/kf\/Sdf27ad30072d454ba8cb5fbb8876c81aZ.jpg\" width=\"900.6944580078125\"\u003e\u003cimg style=\"width: 900.6944580078125px;display: block; margin-left: auto; margin-right: auto;\" src=\"https:\/\/ae-pic-a1.aliexpress-media.com\/kf\/S39f346cd88cc4dac983ec7ecae6b162dB.jpg\" width=\"900.6944580078125\"\u003e\u003cimg style=\"width: 900.6944580078125px;display: block; margin-left: auto; margin-right: auto;\" src=\"https:\/\/ae-pic-a1.aliexpress-media.com\/kf\/S20379abfecec47b2bbc7f4440a416be2v.jpg\" width=\"900.6944580078125\"\u003e\u003cimg style=\"width: 900.6944580078125px;display: block; margin-left: auto; margin-right: auto;\" src=\"https:\/\/ae-pic-a1.aliexpress-media.com\/kf\/Sad4674974a254f6ab93f5cfd13f77c2dd.jpg\" width=\"900.6944580078125\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\r\n","brand":"54 Energy - Renewable Energy Store","offers":[{"title":"Split 50mm 600A 5A","offer_id":68139351834941,"sku":"1005013124232347-Split 50mm 600A 5A","price":31.38,"currency_code":"USD","in_stock":true},{"title":"Split 50mm 400A 5A","offer_id":68139351867709,"sku":"1005013124232347-Split 50mm 400A 5A","price":31.38,"currency_code":"USD","in_stock":true},{"title":"Split 50mm 1000A 5A","offer_id":68139351900477,"sku":"1005013124232347-Split 50mm 1000A 5A","price":31.38,"currency_code":"USD","in_stock":true},{"title":"Split 50mm 800A 5A","offer_id":68139351933245,"sku":"1005013124232347-Split 50mm 800A 5A","price":31.38,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0853\/3924\/2813\/files\/S581c7a86430a472cb68199ce3ed1109a7.webp?v=1795191332","url":"https:\/\/54energy.net\/products\/tomzn-split-core-current-transformer-current-sensor-ct-400a-600a-800a-1000a-ac-for-energy-meter-kwh-meter-power-monitoring-abs","provider":"54 Energy - Renewable Energy Store","version":"1.0","type":"link"}