Rated Current

SPECIFICATIONS

APP: eWelink

Brand Name: EARU

Certification: CE

Choice: yes

Connection Methods: WiFi 2.4GHz

Frequency: 50/60Hz

High-concerned chemical: None

Impact-resistant voltage: 8kV

Input Power 1: City Power

Input Power 2: Generator

Insulation voltage: 690V AC

Is Smart Device: Yes

Model 1: WIFI 2P AC 220V ATS

Model Number: ATS

Origin: Mainland China

Pole: 2P

Rated Voltage: 220V

Rated working current: 125 A

Tse Class: PC

Type: Mini,Circuit breaker

is_customized: Yes

semi_Choice: yes

1.General

The dual power automatic switch is a newly developed miniature household power switch, which is mainly used to test whether the main power supply or standby power supply is normal. When the normal power supply is abnormal, the standby power supply starts to work immediately, which ensures the continuity, reliability and safety of power supply. This product is specially designed for household rail instailation and is specially used for PZ30 distribution box.

The dual power automatic switch is suitable for emergency power supply systems with 50 or 60Hz and rated(L+N) 230VAC.ATS has the characteristics of solid structure. reliable conversion, convenient installation and maintenance and long service life. It is widely used in various occasions where power failure cannot be sustained, and can be operated by electricity or manually.ATS is composed of TSE and controller.

According to lEC60947-6-1,Part 6-1: multifunctional equipment and switchgear is formulated. it can be seen that ATS is the most qualified low-voltage switchgear and control device.


2.Normal operation time and installation conditions

2.1 Ambient air temperature

The maximum temperature shall not exceed 40℃, the minimum temperature shall not be lower than -5℃, and the average temperature within 24 hours shall not be higher than 35℃.

2.2 Altitude

The altitude of the installation site should not be higher than 2000m.

2.3 Atmospheric conditions

When the maximum temperature reaches 40℃, the relative humidity of the installation site should not exceed 50%; when the temperature is the minimum temperature -5℃, the relative humidity is higher, for example, the temperature is 25℃, and the relative humidity is 90%. Due to the temperature change, special measures should be taken to deal with the occasional condensation on the surface of the product

2.4 Pollution grade

The pollution grade of ATS conforms to grade 3 specified in IEC60947-6-1

2.5 Installation category

The installation type of ATS conforms to the category specified in1EC60947-6-1

2.6 Installation conditions

ATS can be installed vertically in control cabinet or distribution cabinet.Make sure the installation distance meets the requirements in Figure 1.