SPECIFICATIONS
Accuracy Class: 1%
Battery Included: No
Brand Name: EARU
Certification: CE,FCC,RoHS,KC
Choice: yes
DIY Supplies: Electrical
Dimensions: 90*77*75.5mm
Display Type: LCD
High Temperature Alarm: 10℃-85℃ (Adjustable) (Default:85℃)
High-concerned chemical: None
Leakage Current Limit: 10-99A (Adjustable)(Default:30mA)
Lost Current Recovery Delay Time: 1-9999s (Adjustable)(Default:20s)
Max Operating Current: 80A - 99A
Measuring Energy Range: 0-9999999.99kWh
Model Number: EAEMP1C-100-TY-W
Operating Temperature: -30℃~70℃
Operation Voltage: AC80V-300V(Single Phase)
Origin: Mainland China
Over & Under Current Protection Delay: 0000-9999s (Adjustable) (Default:5s)
Over & Under Current Protection Recovery Time: 0000-9999s (Adjustable)(Default:20s)
Over & Under Voltage Protection Recovery Time: 1-9999s (Adjustable) (Default:20s)
Over Current Limit: 1-100A (Adjustable)(Default:80A)
Over Voltage Limit: 120-300V (Adjustable) (Default:275V)
Phase: single phase
Power Supply: AC
Rated Voltage: 220V
Time Threshold of Lost Flow Event: 1-999s (Adjustable) (Default:10s)
Under & Over Voltage Protection Delay: 1-9999s (Adjustable) (Default:3s)
Under Current Limit: 1-100A (Adjustable) (Default:10A)
Under Voltage Limit: 80-210V (Adjustable) (Default:175V)
semi_Choice: yes
Our factory can provide OEM service to manufacture this device with your brand, logo, if you get any need, feel free to contact the buyer!
Product Specification
Rated Voltage: AC220V; Frequency: 50Hz/60Hz
Function:
1.Over Voltage Limit:120-300V (Adjustable)(Default:275V)
2.Under Voltage Limit:80-210V(Adjustable)(Default:175V)
3.Over Current Limit:1-100A (Adjustable) (Default:80A)
4.Under Current Limit:1-100A (Adjustable)(Default:10A)
5.Leakage Current Limit:10-99A (Adjustable) (Default30mA)
6.High Temperature Alarm:10-85℃ (Adjustable) (Default:85℃)
7.Over & Under Voltage Protection Recovery Time:1-9999s (Adjustable)(Default:20s)
8.Over & Under Current Protection Delay:0000-9999s (Adjustable) (Default:5s)
9.Over & Under Current Protection Recovery Time:0000-9999s (Adjustable) (Default:20s)
10.Under & Over VoltageProtection Delay:1-9999s (Adjustable)(Default:3s)
11.Lost Current Recovery Delay Time:1-9999s (Adjustable) (Default:20s)
12.Time Threshold of Lost Flow Event:1-999s (Adjustable)(Default:10s)
13.Energy Consumption Zero Clearing:Default OFF
14.Factory Settings Reset:Default OFF
15.Device Sharing
16.Remote Control
17.Voice Control