SPECIFICATIONS

Brand Name: EARU

Certification: CE

Choice: yes

Electricity Type: AC

High-concerned chemical: None

Main Circuit Rating Current 25A: Main Circuit Rating Current: 25A

Main Circuit Rating Voltage: 220V

Model Number: EACT-2P-2NO-16A 20A 25A 32A 40A 63A

Model Number 2: EACT-2P-1NO1NC-16A 20A 25A 32A 40A 63A

Model Number 3: EACT-2P-2NC-16A 20A 25A 32A 40A 63A

Number of Pole: 2,2

Origin: Mainland China

Phase: 2

Rated Voltage 1: AC110V,AC220V

is_customized: Yes

semi_Choice: yes

Descriptions

EACT 16A -63A House hold AC contactor is mainly designed for AC 50Hz or 60Hz circuits with 230V .Rated operating voltage in AC7a usage ,rated operating voltage up to 230V, rated operating current up to 25A, Rated operating voltage in AC7b usage , rated current to 10A. Using in breaking capacity below 6kA circuit. For distance connect or break the circuit.


Normal working and installation conditions

  •  Ambient temperature:-5°C to +40°C,the average temperature no more than +35°C in 24 hours.

  • Altitude:no more than 2000m.

  • Atmospheric conditions: the relative humidity of the installation place should be no more than 50% when the maximum temperature is +40°C:if under a lower temperature,a higher relative humidity is allowed. The monthly average minimum temperature in the wettest month should not exceed +25°C and the monthly average maximum relative humidity of this month no more than 90%.Besides,the dew on the surface of products caused by temperature change should be taken into consideration.

  •  Class of pollution: class 2.

  • Installation condition: class II.

Application instruction

1. Check whether the contactor agrees with the scope of application and the working condition before installation.

2. During the process of installing pull down the motion stopping component and put the contactor on the safe orbit then push up the motion,stopping component to fix the contactor on the safe orbit avoid loosening and dropping pull down the motion,stopping component if you want to remove the contactor.


Caution

a).Make sure the correct mode of connection

b).Screw down the binding screw during the connection





Afficher tous les détails