Passer aux informations produits
1 de 6

GEYA Type A RCBO Auto Recloser Leakage Circuit Breaker with Overcurrent Protection 40A 30mA RCD Electromagnetic Super Immunised

GEYA Type A RCBO Auto Recloser Leakage Circuit Breaker with Overcurrent Protection 40A 30mA RCD Electromagnetic Super Immunised

Prix habituel $215.14 USD
Prix habituel $0.00 USD Prix promotionnel $215.14 USD
Promotion Épuisé
Frais d'expédition calculés à l'étape de paiement.
Rated Current
Ships From
Poles Number
Quantité

SPECIFICATIONS

Brand Name: GEYA

Type: Earth Leakage

Origin: Mainland China

Rated Voltage: 220V

is_customized: Yes

Type: RCD

Model Number: GYR9NM RCBO Recloser

Is Smart Device: No

Certification: CE

Product Name: Type A/Type AC RCBO Recloser

Recloser Voltage Range: DC12V OR AC220V OR DC24-48V

Control Mode: Auto Recloser

GEYA Type A/Type AC RCBO Automatic Recloser Electromechanical Residual Current Circuit Breaker With Over Current Protection RCD Electromagnetic Super Immunised

In case of unwanted tripping after an electrical fault (earth leakage current )


(This Link is for GRD9L-R type AUTO RECLOSER with TypeA or Type AC RCBO)


**If two handles are all on OFF position, means exist residual current!
**If left handle on OFF position, means MCB failure!



Applications
RCCB+RECLOSER can automatically reclose when RCCB trips unexpectedly, no need for manual closing, reduce the cost of manual maintenance, and eliminate faults in time to improve efficiency. Can be widely used in power grid terminal line, such as meter box, new energy circuit management, PV solar control box, smart electricity, smart home, new energy vehicle charging pile, and so on.

Function Features of recloser (RD)
-Can be matched with RCCB,remote switching and splitting of RCCB.
-With manual / automatic selector switch.
-With mechanical / electronic double locking function.
-Work status is indicated by LED.
-Automatic switch on distribution board when electric trip happen

-Auto reclosing interval time : 10 second > 60second > 300second 
-Built-in 3 reclosing times, continuous closing failure within 15 minutes can send an alarm through auxiliary contact
-Manually Close Reclosing Time: AUTO→MANU→AUTO

Technical Data OF RCCB RECLOSER

HOW TO CHOOSE RCCB RECLOSER Control Mode?

Recloser 8 type choice:

GRD9L-C-DC= Recloser is Swicth Input Control Mode, DC12V or DC24~48V

GRD9L-C-AC= Recloser is Swicth Input Control Mode, AC220V

(For example: Connect with Relay, as a switch)

GRD9L-D-DC= Recloser is Controlled by switch+Auto Reclosing, DC12V or DC24~48V

GRD9L-D-AC= Recloser is Controlled by switch+Auto Reclosing, AC220V


GRD9L-S-DC= Recloser is RS485 Control Mode, DC12V or DC24~48V

GRD9L-S-AC= Recloser is RS485 Control Mode, AC220V

(Connect with Computer or PLC)

GRD9L-R-DC= Recloser is Auto Reclose Control Mode, DC12V or DC24~48V

GRD9L-R-AC= Recloser is Auto Reclose Control Mode, AC220V

(Autoreclose time 10s, 60s, 300s...)


If you need other recloser function, please click here!



Company Information




Afficher tous les détails