SPECIFICATIONS
Accuracy Class: ±1%
Battery Included: No
Brand Name: EARU
Certification: CE,FCC
Choice: yes
DIY Supplies: Electrical
Dimensions: 73*51*59mm
Display Mode: Display Mode 1and2 (Default:Display Mode 1)
Display Type: LCD
High Temperature Alarm: 10℃-85℃ (Adjustable) (Default:85℃)
High-concerned chemical: None
Leakage Current Limit: 10-99A (Adjustable)(Default:29mA)
Lost Current Recovery Delay Time: 1-9999s (Adjustable)(Default:20s)
Max Operating Current: 80A - 99A
Measuring Energy Range: 0-99999.99kWh
Model Number: EASEM-G-TY-W
Operating Temperature: -30℃~70℃
Operation Voltage: AC80V-400V(Single Phase)
Origin: Mainland China
Over & Under Current Protection Delay: 0000-9999s (Adjustable) (Default:5s)
Over & Under Current Protection Recovery Time: 0000-9999s (Adjustable)(Default:20s)
Over & Under Voltage Protection Recovery Time: 1-9999s (Adjustable) (Default:20s)
Over Current Limit: 1-100A (Adjustable)(Default:80A)
Over Voltage Limit: 120-300V (Adjustable) (Default:275V)
Phase: Three Phase
Power Source: AC
Power Supply: AC
Rated Voltage: 380V
Three-Phase Current Imbalance Alarm: 10-100% (Adjustable) (Default:20%)
Time Threshold of Lost Flow Event: 1-999s (Adjustable) (Default:10s)
Under & Over Voltage Protection Delay: 1-9999s (Adjustable) (Default:3s)
Under Current Limit: 1-100A (Adjustable) (Default:10A)
Under Voltage Limit: 80-210V (Adjustable) (Default:175V)
Voltage Three-Phase Imbalance Alarm: 0-100% (Adjustable)(Default:20%)
semi_Choice: yes
Our factory can provide OEM service to manufacture this device with your brand, logo, if you get any need, feel free to contact the buyer!
Product Specification
Rated Voltage: AC380V;
Operation Voltage:AC80V-400V(Single Phase);
Frequency: 50Hz/60Hz
Function:
1.Over Voltage Limit:120-300V (Adjustable)(Default:275V)
2.Under Voltage Limit:80-210V(Adjustable)(Default:175V)
3.Over Current Limit:1-100A (Adjustable) (Default:80A)
4.Under Current Limit:1-100A (Adjustable)(Default:10A)
5.Leakage Current Limit:10-100mA (Adjustable) (Default:30mA)(Used with Transformers)
6.High Temperature Alarm:10-85℃ (Adjustable) (Default:85℃)
7.Display Mode:Display Mode 1、2 (Default:Display Mode 1)
8.Over & Under Voltage Protection Recovery Time:1-9999s (Adjustable)(Default:20s)
9.Over & Under Current Protection Delay:0000-9999s (Adjustable) (Default:5s)
10.Over & Under Current Protection Recovery Time:0000-9999s (Adjustable) (Default:20s)
11.Under & Over VoltageProtection Delay:1-9999s (Adjustable)(Default:3s)
12.Three-Phase Current Imbalance Alarm:10-100% (Adjustable) (Default:20%)
13.Voltage Three-Phase Imbalance Alarm:0-100% (Adjustable)(Default:20%)
14.Lost Current Recovery Delay Time:1-9999s (Adjustable) (Default:20s)
15.Time Threshold of Lost Flow Event:1-999s (Adjustable)(Default:10s)
16.Energy Consumption Zero Clearing:Default OFF
17.Factory Settings Reset:Default OFF
18.Device Sharing
19.Remote Control
20.Voice Control
NOTE: A circuit breaker and a shunt trip device are required for protection functions, which are not included in the package. If required, users should purchase them separately!