SPECIFICATIONS
Active time range: 0.1-60s
Brand Name: TOMZN
Certification: CE
Delay off time range: 1-512s
Delay on time range: 2-255s
Does it include a Battery?: No
Does it include wireless functionality?: No
EU LVD Voltage: High voltage: Above 50Vac or 75Vdc
High-concerned chemical: None
Is Smart Device: no
Model Number: DDS238-VAP-W
Origin: Mainland China
Over current protection range: 1-63A ( default 40A)
Overvoltage protection range: 85-300V ( default 270V)
Rated frequency: 50/60Hz
Type: Mini,Voltage relay
Under voltage protection range: 85-300V ( default 170V)
is_customized: Yes
DDS238-VAP 2P 85-300VAC 63A
Adjustable Over Voltage & Over Current Protector Under Current Protection Relay Power Monitoring Device
General description
The DDS238-VAP-W water pump protection device is used to measure the active energy of single-phase two-wire AC circuits, and realizes the automatic control of water pump operation.
Product features
1. Equipped with backlit LCD display, it can clearly show total active energy (kWh), real-time current (A), voltage (V) and active power (W).
2. Adopts self-developed circuit design with built-in lightning protection function.
3. Supports overvoltage protection and delayed power-on restart protection.
4. Enables automatic water pump control. Users can set upper and lower current thresholds to determine pump start/stop status. The pump current decreases when the pipeline is dry and increases when the water tower is full. Auto-reclosing or manual-reclosing mode is available for pump operation.
5. Allows setting of cyclic working time for the water pump.
6. LED indicators clearly show overvoltage protection status, upper/lower current limit protection status and power status.
7. Automatically disconnects the load when power failure occurs.
Specification and Technical Parameters
Input working voltage |
85~300V |
Overvoltage protection value |
85-300V ( default 270V) |
Current limit |
1-63A ( default 40A) |
Rated frequency |
50/60Hz |
Delay in switch on after power off |
2-255V ( default 2s) |
Voltage circuit power consumption |
≤1W |
Current circuit power consumption |
<1VA |
Active energy display range |
0~9999.9kWh |
Voltage/current/active power accurate |
0.50% |
Active energy accurate |
+1% (IEC62053-21) |
Operating temperature |
-25℃~+70℃ |
Storage temperature |
-40℃~+80℃ |
Relative humidity |
≤85% |
Altitude |
≤2500m |
Electromagnetic Environment |
E2 |
Mechanical life |
≥100000 cycles |