Rated Current
Poles Number
Quantity

SPECIFICATIONS

Active time range: 0.1-60s

Brand Name: TOMZN

Certification: CE

Delay off time range: 1-512s

Delay on time range: 2-255s

Does it include a Battery?: No

Does it include wireless functionality?: No

EU LVD Voltage: High voltage: Above 50Vac or 75Vdc

High-concerned chemical: None

Is Smart Device: no

Model Number: DDS238-VAP-W

Origin: Mainland China

Over current protection range: 1-63A ( default 40A)

Overvoltage protection range: 85-300V ( default 270V)

Rated frequency: 50/60Hz

Type: Mini,Voltage relay

Under voltage protection range: 85-300V ( default 170V)

is_customized: Yes

DDS238-VAP 2P 85-300VAC  63A 
Adjustable Over Voltage & Over Current Protector Under Current Protection Relay Power Monitoring Device

General description

The DDS238-VAP-W water pump protection device is used to measure the active energy of single-phase two-wire AC circuits, and realizes the automatic control of water pump operation.

This product is equipped with overvoltage protection, and can automatically cut off the power supply of the water pump when the water tower is full or there is no water in the pipeline.
It can effectively reduce water waste, and prevent the water pump motor from overheating and damage caused by continuous long-time operation.

Product features

1. Equipped with backlit LCD display, it can clearly show total active energy (kWh), real-time current (A), voltage (V) and active power (W).

2. Adopts self-developed circuit design with built-in lightning protection function.

3. Supports overvoltage protection and delayed power-on restart protection.

4. Enables automatic water pump control. Users can set upper and lower current thresholds to determine pump start/stop status. The pump current decreases when the pipeline is dry and increases when the water tower is full. Auto-reclosing or manual-reclosing mode is available for pump operation.

5. Allows setting of cyclic working time for the water pump.

6. LED indicators clearly show overvoltage protection status, upper/lower current limit protection status and power status.

7. Automatically disconnects the load when power failure occurs.

Specification and Technical Parameters

Input working voltage

85~300V

Overvoltage protection value

85-300V ( default 270V)

Current limit

1-63A ( default 40A)

Rated frequency

50/60Hz

Delay in switch on after power off

2-255V ( default 2s)

Voltage circuit power consumption

≤1W

Current circuit power consumption

<1VA

Active energy display range

0~9999.9kWh

Voltage/current/active power accurate

0.50%

Active energy accurate

+1% (IEC62053-21)

Operating temperature

-25℃~+70℃

Storage temperature

-40℃~+80℃

Relative humidity

≤85%

Altitude

≤2500m

Electromagnetic Environment

E2

Mechanical life

≥100000 cycles




View full details