TOMZN Adjustable Over Voltage Relay Current Limit Under Current Protector V-I-kW-kWh Display AC110V 230V 63A Water Level Control
TOMZN Adjustable Over Voltage Relay Current Limit Under Current Protector V-I-kW-kWh Display AC110V 230V 63A Water Level Control
Couldn't load pickup availability
SPECIFICATIONS
Active time range: 0.1-60s
Brand Name: TOMZN
Certification: CE
Delay off time range: 1-512s
Delay on time range: 2-255s
Does it include a Battery?: No
Does it include wireless functionality?: No
EU LVD Voltage: High voltage: Above 50Vac or 75Vdc
High-concerned chemical: None
Is Smart Device: no
Model Number: DDS238-VAP-W
Origin: Mainland China
Over current protection range: 1-63A ( default 40A)
Overvoltage protection range: 85-300V ( default 270V)
Rated frequency: 50/60Hz
Type: Mini,Voltage relay
Under voltage protection range: 85-300V ( default 170V)
is_customized: Yes
DDS238-VAP 2P 85-300VAC 63A
Over voltage protection、Over current protection、Under current protection(without under voltage protection).
General description
DDS238-VAP-W type water pump Protective Device is designed to measure single phase two wire AC active energy and control water pump automatic working. This device have over voltage protection function and it can cut off the water pump when the water tower is full or no water in the pipe. So it can help people to reduce water waste and avoid the water pump motor over-temperature destroyed for long time working.
Product features
1. LCD display with backlight , can display total active energy (kWh) , real time current (A) , voltage(V) , active power (W) .
2. Product self-design has function of lighting protection
3. Overvoltage protection and delay power on protection
4. Control water pump automatic working. We can set a lower limit and upper limit to check whether should make the water pump on or off . because the water pump work current will drop when no water in the pipe and the water pump work current will rise when the water tower is full . We can select auto-Reclosing mode or manual--Reclosing mode to drive the water pump work .
5. it also can set water pump recycle working time
6. Led indication of overvoltage protection, upper limit current protection ,lower limit current protection , power
7. switch off the load when power off
Product parameters
Input working voltage |
85~300V |
Overvoltage protection value |
85-300V ( default 270V) |
Current limit |
1-63A ( default 40A) |
Rated frequency |
50/60Hz |
Delay in switch on after power off |
2-255V ( default 2s) |
Voltage circuit power consumption |
≤1W |
Current circuit power consumption |
<1VA |
Active energy display range |
0~9999.9kWh |
Voltage/current/active power accurate |
0.50% |
Active energy accurate |
+1% (IEC62053-21) |
Operating temperature |
-25℃~+70℃ |
Storage temperature |
-40℃~+80℃ |
Relative humidity |
≤85% |
Altitude |
≤2500m |
Electromagnetic Environment |
E2 |
Mechanical life |
≥100000 cycles |