TOMZN TO219G 1P 2P 3P 4P 40A 63A MTS Dual Power Manual Transfer Isolating Switch Interlock Circuit Breaker Blue Generator PV
TOMZN TO219G 1P 2P 3P 4P 40A 63A MTS Dual Power Manual Transfer Isolating Switch Interlock Circuit Breaker Blue Generator PV
Couldn't load pickup availability
SPECIFICATIONS
Brand Name: TOMZN
Certification: CE
Does it include a Battery?: No
Does it include wireless functionality?: No
EU LVD Voltage: High voltage: Above 50Vac or 75Vdc
High-concerned chemical: None
Is Smart Device: no
Model Number: TO419G NEW
Origin: Mainland China
Rated Voltage: 220/380V
Type: Mini,Circuit breaker
is_customized: Yes
Model:
TO119G 1P 230V AC 40A/63A
TO219G 2P 230V AC 40A/63A
TO319G 3P 230V AC 40A/63A
TO419G 4P 230V AC 40A/63A
General
A Manual Transfer Switch (MTS) is a critical electrical device designed to provide reliable power supply for essential circuits. It serves as a secure bridge between two independent power sources, typically the utility power (main source) and a generator (backup source).
1. Safe Power Source Transfer
The primary function is to manually shift the electrical load from a failed or de-energized main power source to a live backup source. This ensures that critical systems and equipment can continue operating without prolonged interruption.
2. Complete Electrical Interlocking
A key safety mechanism ensures that both power sources can never be connected simultaneously. This prevents back-feeding, which could cause severe short circuits, damage equipment, and pose a serious hazard to utility workers.
3. Isolation and Operator Control
It features a clear "OFF" or "Open" position, allowing for complete physical isolation of the load from both sources. This enables safe maintenance and servicing.
Operation is direct and intentional, with clearly marked positions (e.g., "Line 1," "Line 2," "Off"). This manual, non-automated process gives operators full control and eliminates the risk of unintended automatic switching.
Basic Function
TO119G 1P 400V AC
1P Manual Transfer Switch(MTS)
1.When the handle on the I position: 1 and 2 are connected
2.When the handle on the II position: 1 and 4 are connected
3.When the handle is in the middle position: both groups are disconnected.
TO219G 2P 400V AC
2P Manual Transfer Switch(MTS)
1.When the handle on the I position:
1 and 2 are connected
5 and 6 are connected.
2.When the handle on the II position:
1 and 4 are connected
5 and 8 are connected.
3.When the handle is in the middle position: both groups are disconnected.
TO319G 3P 400V AC
3P Manual Transfer Switch(MTS)
1.When the handle on the I position:
1 and 2 are connected
5 and 6 are connected.
9 and 10 are connected
2.When the handle on the II position:
1 and 4 are connected
5 and 8 are connected.
9 and 12 are connected
3.When the handle is in the middle position: both groups are disconnected.
TO419G 4P 400V AC
4P Manual Transfer Switch(MTS)
1.When the handle on the I position:
1 and 2 are connected
5 and 6 are connected
9 and 10 are connected
13 and 14 are connected.
2.When the handle on the II position:
1 and 4 are connected
5 and 8 are connected
9 and 12 are connected
13 and 16 are connected.
3.When the handle is in the middle position: both groups are disconnected.
The position of the incoming and outgoing wires can be adjusted according to actual needs (the upper and lower out are not necessarily required, when used for dual power switching, the lower in and upper out must be used.)